Fan Still Doesn't Work - Tried Sooo Many Things

V6 Technical/Performance Discussions
davio8
Junior Member
Posts: 5
Joined: July 5th, 2007, 4:58 am

Fan Still Doesn't Work - Tried Sooo Many Things

Post by davio8 »

Hey guys
So i realized my coolant has been leaking from the top, which then i noticed my fan would not turn on. I tried so many things and it still doesn't work. Ill list them:

-changed radiator cap
-changed thermostat
-changed oil filter
-changed engine coolant temp. sensor
-connected fan to battery, and it worked
-tested the fan relay as it says in shop manual and fan relay works
-flushed out all coolant and new clean one is in


Thats all I can thing of that I can do. I don't wanna send my car to a mechanic and gotta pay 200 bucks on something I could've done myself. So anyone got any other ideas I can try?

Thanks a lot
User avatar
Mooneggs
Forum Moderator
Posts: 6128
Joined: August 10th, 2005, 10:08 pm
antispam: ~SPAM*SUX~
Location: Hillsboro, OR
Contact:

Post by Mooneggs »

Isn't there a fuse for the fan?
Mnemonic
Forum Moderator
Posts: 3415
Joined: September 3rd, 2002, 2:01 am
Location: Eastern Hemisphere
Contact:

Post by Mnemonic »

are you sure you replaced the correct temp sensor?
08 Infiniti G37s 6speed (The Daily)
Stillen Cold Air Intake, Z1 Plenum Power Mod, Z1 Headers, Z1 Test Pipe, OBX (Ark) Exhaust, Up-Rev Osiris Engine Management (Tuned at Z1), 20x9" 20x10" Str Racing Concave Staggered Rims, SPC Camber kit, Tein H Techs Springs

01 Lexus Is300 (LS2 Project)
93 Mx3 SE 2.5 KLZE (sold it)
93 Mx3 GS 2.0 KFZE (killed it)
davio8
Junior Member
Posts: 5
Joined: July 5th, 2007, 4:58 am

Post by davio8 »

the fuse is good and ya I changed the correct sensor. I followed it on the shop manual.
User avatar
mx3autozam
Senior Member
Posts: 2950
Joined: September 24th, 2005, 9:09 pm
Location: Kitchener

Post by mx3autozam »

do you have a klze? with a klze ecu???
93 Mazda MX3 KLZE Turbo
Red Rocket
Regular Member
Posts: 185
Joined: January 6th, 2006, 7:42 pm
Location: Cobourg, Ontario

Post by Red Rocket »

try turning your ac on, the fan should come on then
[*url=http:cardomain.com/ride/2632839]My Cardomain Page[/url*]
User avatar
mx3autozam
Senior Member
Posts: 2950
Joined: September 24th, 2005, 9:09 pm
Location: Kitchener

Post by mx3autozam »

Red Rocket wrote:try turning your ac on, the fan should come on then
if he has ac there is a seperate fan for that!
93 Mazda MX3 KLZE Turbo
User avatar
tehbrookzorz
Regular Member
Posts: 1561
Joined: April 29th, 2006, 6:59 pm
Location: Calgary, Alberta

Post by tehbrookzorz »

Well what are the possibilities? Fan motor, relay, switch, fuse, Temp sensor. ECM or wiring, right?
Cody
Image
Red Rocket
Regular Member
Posts: 185
Joined: January 6th, 2006, 7:42 pm
Location: Cobourg, Ontario

Post by Red Rocket »

mx3autozam wrote:
Red Rocket wrote:try turning your ac on, the fan should come on then
if he has ac there is a seperate fan for that!

When I have my ac activated both fans run. :?
[*url=http:cardomain.com/ride/2632839]My Cardomain Page[/url*]
hgallegos915
Senior Member
Posts: 6451
Joined: June 19th, 2004, 2:01 am
Location: El Paso Tx U.S
Contact:

Post by hgallegos915 »

why dont you wire it to the battery and see if its the fan? If all fails. wire them to a switch. I got both fans wired to switches. For drag racing (at the line) I turn both of them.
-hec

MX-3 w/ curved neck millenia klde, boosted @ 5 psi. /bov and wastegate are good!/ nitto drag radial/ gutted interior/ millenia red top injectors, vortech fmu/aem wideband/ all bolts ons/ Car put together 100% by me. Mechanic? who needs a mechanic? ew.. real men work on their own cars!
User avatar
shameem
Supporting Member
Posts: 820
Joined: May 9th, 2007, 9:59 pm

Post by shameem »

Try cleaning the connector right next to the fan - use a small file to remove all corrosion and spray on some electric cleaner and then apply di-electric grease to prevent further corrosion.
lutos
Regular Member
Posts: 58
Joined: January 14th, 2007, 8:36 pm

Post by lutos »

if the fan works jus hard wire the fan to a manual switch
User avatar
94mx3precidia
Regular Member
Posts: 574
Joined: May 12th, 2007, 8:00 pm
Location: Thunder Bay, Ontario

Post by 94mx3precidia »

cutos to lutos, lol
1994 MX-3 GS KLZE, Probinator, Bully stage 1 (probe GT), B&M Short Shifter, 2 1/4" Custom headders back.
davio8
Junior Member
Posts: 5
Joined: July 5th, 2007, 4:58 am

Post by davio8 »

thanks guys for the input

ill try cleaning the connecter but i found the problem. there is no electricty running to the sensors. all fuses are good, but anyone know if there is any hidden fuses in the middle of the wiring anywhere?

thanks
User avatar
94mx3precidia
Regular Member
Posts: 574
Joined: May 12th, 2007, 8:00 pm
Location: Thunder Bay, Ontario

Post by 94mx3precidia »

i dont know if ts for the blower motor but there is one near he fusebox in the car. its not really a fuse, more of a breaker. it should say FAN 30AMP on a small rectangular box.
1994 MX-3 GS KLZE, Probinator, Bully stage 1 (probe GT), B&M Short Shifter, 2 1/4" Custom headders back.